Der Ultraschall-Durchflussmesser verwendet das Zeitdifferenzprinzip der Ultraschallwellenausbreitung im Medium, um die Durchflussrate zu messen. Es wird hauptsächlich verwendet, um Flüssigkeiten zu messen, wie z. Pflanzenabwasser usw.
Der Ultraschall-Durchflussmesser besteht aus Sender und Sensoren
Ultraschall-Durchflussmesser GUF120A-I für bauseitige Montage
Ultraschall-Durchflussmesser GUF120-P für Schalttafeleinbau
GUF120-M Ultraschall-Durchflussmesser für Hutschienenmontage
Ultraschall-Durchflussmesser GUF120-E für explosionsgeschützte Bedingungen .
Items |
Performance & Parameter |
||
Host
|
Principle |
Transit- time ultrasonic flowmeter |
|
Accuracy |
±1% |
||
Display |
2X20 character LCD with backlight, support the language of Chinese, English and Italy |
||
Signal Output |
1 way 4~20mA output, electric resistance 0~ 1K, accuracy 0. 1%(optional) 1 way OCT pulse output(Pulse width 6~1000ms, default is 200ms) 1 way Relay output |
||
Signal Input |
3 way 4~20mA input, accuracy 0. 1%, acquisition signal such as temperature, press and liquid level |
||
Connect the temperature transducer Pt100, can finish the heat/energy measurement |
|||
Data Interface |
Insulate Rs485 serial interface, upgrade the flowmeter software by computer, support the MODBUS |
||
Special Cable |
Twisted-pair cable, generally, the length under 50 meters ; Select the RS485, transmission distance can over 1000m |
||
Pipe Installation Condition |
Pipe Material |
Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed |
|
Pipe Diameter |
DN32~6000mm |
||
Straight Pipe |
Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump |
||
Measuring Medium |
Medium |
water,sea water ,alcohol,Acid and alkali,waste water,beer,all kinds of oil Single liquid can transmit sound wave. |
|
Temperature |
-30~160℃ |
||
Turbidity |
No more than 10000ppm and less bubble |
||
Flowrate |
0~±7m/s,Forward and backward measurement |
||
Work environment |
Host:IP67;flow sensor:IP68 |
||
temperature |
Host:-20~60℃;flow sensor:-30~ 160℃ |
||
Humidity |
Host: 85%RH; Flow sensor:can measure under water, water depth^2m (tansducer sealed glue) |
||
Power Supply |
DC8~36V or AC85~264V |
||
Power Consumption |
1.5W |
||
Dimension |
132*150*85mm(host) |