Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator
Feedback Grid Simulator

1 / 5

Feedback Grid Simulator

  • $19999.00

    ≥1 Set/Sets

Color:

  • Light Grey
Anfrage absenden
Model No. :
Brand Name :
Warranty Service : 1 Year
After-sales service : Online Technical Support,Free Spare Parts
Material : Stainless Steel
Engineering solution capability : Others
Application scenario : Workshop
design style : Chinese,Traditional
place of origin : China
Type : Regenerative
Power : 30kva-1000kva
mehr
4yrs

Jinan, Shandong, China

Besuchen Sie den Laden
  • Gold-Lieferant
  • Plattformzertifizierung

Produktbeschreibung

Regenerationsgittersimulator

Der Raster-Simulator der XYH-Serie nimmt die digitale PWM-Rekorde-Technologie und die unabhängige Hochfrequenz-Wechselrichtertechnologie an, wobei vier Quadrantenbetriebsfunktionen der Zwei-Wege-Energiefluss realisieren. Die Leistung umfasst 15kVA-1MVA und kann für 2 bis 40 harmonische Tests überlagert werden. Mehrere Ausgangsmodi, um "eine Maschine für mehrere Zwecke" zu erreichen und die Anforderungen der einphasigen/dreiphasigen Geräte zu erfüllen.

Anwendungsbereich

PV- und Energiespeicher Wechselrichter

Ladehaufen

Frequenzumwandler

UPS

Produktmerkmale

(1) mit mehreren Ausgangsmodi und leistungsstarken Funktionen;

Drei-Phasen-Standardmodus: Standarddreiphasenspannungsausgang;

Drei-Phasen-Ungleichgewichtsmodus: Die Dreiphasenspannung wird unabhängig eingestellt und der Phasenwinkel mit drei Phasen ist von 0,0 ° bis 359,9 ° einstellbar;

Paralleler einphasiger Modus: Dreiphasen parallel zur Hochleistungs-Einphasendution ;

(2) Dreiphasen -Entkopplungsdesign wird mit umfassender Funktionsnetz -Anomalie -Simulationsfunktion angewendet: Leistungsnetzverzerrung, Stromnetzfluktuation,

Drei-Phasen-Ungleichgewicht usw. und 2-40 Harmonische können im harmonischen Modus überlagert werden

(3) Es verfügt über vier Quadrantenbetriebsfunktion

(4) Erfüllen Sie die im NB/T32004-2013 Standard angegebene Testeranforderungen (Null) Spannungsfahrt und die niedrige (Null) Spannungsfahrt durch die Leistung ist zuverlässig, ohne Resonanz mit der Last bei niedriger Spannung

(5) Erfüllen Sie die Hochspannungsfahrt durch die im internationalen Standard angegebenen Testanforderungen

(6) schnelle dynamische Reaktion

(7) hoher Eingangsleistungspunkt (≥ 0,95), niedriger Eingangsstromverzerrung (< 5%)

(8) Mit der automatischen Sperrfunktion wird die Tastatur in regelmäßigen Abständen automatisch gesperrt, um zu verhindern, dass ein versehentlicher Kontakt menschliche Unfälle oder Gefahren verursacht

(9) 8-Zoll-Farb-LCD-Bildschirm mit zartem Erscheinungsbild und bequemem Betrieb ist mit Zahlenschlüssel, Funktionstasten, Knöpfen usw. ausgestattet, und der Betrieb ist diversifiziert

(10) Komplette Messfunktionen, in der Lage, Spannung, Strom, Stromspitzen, Frequenz, aktive Leistung, scheinbare Leistung, Leistungsfaktor, Spannungspeakfaktor und andere elektrische Energieparameter zu messen

(11) Mit der AI -Überwachungsfunktion kann sie die interne Spannung, den Strom, die Temperatur und andere Parameter in Echtzeit überwachen, unmittelbar bei abnormalen Bedingungen alarmieren und eine rechtzeitige Handhabung auffordern

(12) Mit Black Box -Funktion kann es automatisch Betriebsparameter unter abnormalen Bedingungen für die spätere Inspektion und Wartung aufzeichnen.

(13) Die Kommunikationsschnittstelle ist standardmäßig mit RS232, RS485, GPIB, Ethernet, Analog Control usw. als Optionen ausgestattet

Technischer Parameter:

Technischer Parameter

Name

Feedback Grid simulator

Model

XYH015-3X

XYH030-3X

XYH045-3X

XYH060-3X

XYH090-3X

XYH120-3X

XYH150-3X

XYH180-3X

XYH240-3X

Output/absorption

15kVA

30kVA

45kVA

60kVA

90kVA

120kVA

150kVA

180kVA

240kVA

Basic function

Output

Power grid simulation function

Feedback

The output energy is fed back to the grid

Isolation

Built in isolation transformer

Load power factor

+1.0 1.0

Wiring mode

Input terminal: 3P4W terminal: 3P4W/1P2W (automatic switching according to output mode)

Input

Phase

3P4W+PE

Voltage range

380V±57V(L-L)

Frequency range

4565Hz

Power factor

0.97 (input rated voltage, input 50% - 100% rated current)

0.95 (input rated voltage, input 10% - 50% rated current)

Current distortion

3% (under rated conditions)

Output

Phase

3P4W or 1P2W

Mode

3P standard mode, 3P unbalanced mode, parallel 1P

Voltage

0.0300.0V(L-N)

Voltage setting accuracy

Precision: ≤ 0.5% Resolution: 0.1V

3P standard mode, 3P unbalanced mode

Rated current

22.7A

45.4A

68.1A

90.9A

136.3A

181.8A

227.2A

272.7A.

363.6A

Parallel 1P mode

Rated current

68.1A

136.3A

204.5A

272.7A

409.1A

545.4A.

681.8A

818.1A

1090.9A

Frequency

45.0065.00Hz

Frequency accuracy

Precision: ≤ 0.02% Resolution: 0.01Hz

Frequency stability

≤0.02%

Voltage distortion (VTHD)

1% (linear load)

Reaction time

≤2ms

Response time of voltage sudden change

≤20ms

Three phase angle

120°±2°(3P standard mode)

Crest factor

1.41 ± 0.1 (sine wave mode)

Source voltage effect

≤1%

Load effect

≤1%

Efficiency

86%

Measurement display

Display mode

8-inch color LCD screen

Voltage measurement accuracy

Precision: 0.2% FS+0.2% Display value resolution: 0.1V

Frequency measurement accuracy

Precision: 0.02% Resolution: 0.01Hz

Current measurement accuracy

Precision: 0.3% FS+0.3% Display value resolution: 0.1A/1A

Power measurement accuracy

Precision: 0.5% FS+0.5% Display value resolution: 0.1kW/0.01kW/0.001kW

Function operation

Ladder programming

9999 steps

Step programming

100 steps, 999999times cycle

Gradient Programming

100 steps, 999999times cycle

Low (zero) voltage ride through

It can simulate international standards, and the minimum response time is ≤ 20ms

High voltage ride through

It can simulate international standards, and the minimum response time is ≤ 20ms

Waveform system

Sine wave or harmonic wave (superposition of 2~40times harmonic wave)

Real time adjustment function

Under the starting state of the normal mode, the output voltage and frequency setting values can be adjusted through the number keys, increase/decrease keys and knobs, and they can be updated immediately

Under normal mode startup status, the output waveform system can be switched and updated immediately

Quick call

10 groups of fast groups in conventional mode 10 groups of fast groups in harmonic mode

Protection function

Overload capacity

Cut off the output after 15 seconds when 105% overload ≤ 110%

Cut off the output after 5 seconds when 110% overload ≤ 200%

Cut off the output after 2 seconds when 200% overload ≤ 300%

Cut off output immediately when 300% overload

Protect

Over current, overload, short circuit protection, overheat protection, output overvoltage and undervoltage, phase loss protection, bus overvoltage and undervoltage, output power contactor automatic tripping protection

software protection

AI Monitor function, Black Box function, Auto Lock key lock protection

Remote interface

communication interface

Standard configuration: RS232 Optional configuration: RS485, GPIB, ETHERNET

Remote control

Optional: analog control port

Work environment

 Temperature

040

Humidity

2090%RH(Non condensing)

Volume weight

Size(W×H×Dmm)

1000×2000×800

1800×2000×800

2100×2000×1000

2400×2000×1000

Weight(Kg)

510

600

750

1050

1350

1500

1650

1850

2100


Name

Feedback Grid simulator

Model

XYH300-33

XYH400-33

XYH500-33

XYH600-33

Output/absorption

300kVA

400kVA

500kVA

600kVA

Basic function

Output

Power grid simulation function

Feedback

The output energy is fed back to the grid

Isolation

Built in isolation transformer

Load power factor

+1.0 1.0

Wiring mode

Input terminal: 3P4W terminal: 3P4W/1P2W (automatic switching according to output mode)

Input

Phase

3P4W+PE

Voltage range

380V±57V(L-L)

Frequency range

4565Hz

Power factor

0.97 (input rated voltage, input 50% - 100% rated current)

0.95 (input rated voltage, input 10% - 50% rated current)

Current distortion

5% (under rated conditions)

Output

Phase

3P4W or 1P2W

Mode

3P standard mode, 3P unbalanced mode, parallel 1P

Voltage

0.0300.0V(L-N)

Voltage setting accuracy

Precision: ≤ 0.5% Resolution: 0.1V

Rated current

454.5A

606.0A

757.5A

909.0A

Frequency

45.0065.00Hz

Frequency accuracy

Precision: ≤ 0.02% Resolution: 0.01Hz

Frequency stability

≤0.02%

Voltage distortion (VTHD)

3% (linear load)

Reaction time

≤2ms

Response time of voltage sudden change

≤20ms

Three phase angle

120 °± 2 ° (3P standard mode)

Crest factor

1.41 ± 0.1 (sine wave mode)

Source voltage effect

≤1%

Load effect

≤1%

Efficiency

85%

Test display

Display mode

8-inch color LCD screen

Voltage measurement accuracy

Precision: 0.2% FS+0.2% Display value resolution: 0.1V

Frequency measurement accuracy

Precision: 0.02% Resolution: 0.01Hz

Current measurement accuracy

Precision: 0.3% FS+0.3% Display value resolution: 0.1A/1A

Power measurement accuracy

Precision: 0.5% FS+0.5% Display value resolution: 0.1kW/0.01kW/0.001kW

Function operation

Ladder programming

9999 steps

Step programming

100 steps, 999999times cycle

Gradient Programming

100 steps, 999999times cycle

Low (zero) voltage ride through

It can simulate international standards, and the minimum response time is ≤ 20ms

High voltage ride through

It can simulate international standards, and the minimum response time is ≤ 20ms

Waveform system

Sine wave or harmonic wave (superposition of 2~40times harmonic wave)

Real time adjustment function

Under the starting state of the normal mode, the output voltage and frequency setting values can be adjusted through the number keys, increase/decrease keys and knobs, and they can be updated immediately

Under normal mode startup status, the output waveform system can be switched and updated immediately

Quick call

10 groups of fast groups in conventional mode 10 groups of fast groups in harmonic mode

Ladder programming

9999 steps

Protection function

Overload capacity

Cut off the output after 15 seconds when 105% overload ≤ 110%

Cut off the output after 5 seconds when 110% overload ≤ 200%

Cut off the output after 2 seconds when 200% overload ≤ 300%

Cut off output immediately when 300% overload

Protect

Over current, overload, short circuit protection, overheat protection, output overvoltage and undervoltage, phase loss protection, bus overvoltage and undervoltage, output power contactor automatic tripping protection

software protection

AI Monitor function, Black Box function, Auto Lock key lock protection

Overload capacity

Protect

Over current, overload, short circuit protection, overheat protection, output overvoltage and undervoltage, phase loss protection, bus overvoltage and undervoltage, output power contactor automatic tripping protection

software protection

AI Monitor function, Black Box function, Auto Lock key lock protection

Work environment

Temperature

040

Humidity

2090%RH(Non condensing)

Volume

Size(W×H×Dmm)

4200×2000×1200

4800×2000×1400

4800×2000×1400

8000×2000×1400



Company Overview

Jinan Xinyuhua Energy Technology Co., Ltd. firmly grasps the direction of "low-carbon economy and green development", takes "building a first-class new energy enterprise in China and even in the world" as its strategic goal, carries forward the enterprise spirit of "harmony, innovation and pur

Mehr sehen
Company Photos
Anfrage absenden

Produktalarm

Abonnieren Sie Ihre interessierten Schlüsselwörter. Wir werden die neuesten und heißesten Produkte frei in Ihren Posteingang senden. Verpassen Sie keine Handelsinformationen.