Model No. : YJQS03
Brand Name : HUAYUAN YONGTONG
Type : Insulated
Conductor Type : Stranded
Application : Underground
Conductor Material : Copper
Sheath Material : Crosslinking
Insulation Material : XLPE
Material Shape : Round Wire
Range of Application : LSOH
Certification : ISO9001
Brand : HUAYUAN YONGTONG
mehr
8yrs

Beijing, Beijing, China

Besuchen Sie den Laden
  • Plattformzertifizierung
  • Video

Produktbeschreibung

1. ALLGEMEINES

Diese gelistete Spezifikation deckt die Struktur, die Leistung, die Test- und Verpackungsinformationen von EHV Power Cable ab, wie sie von Beijing Huayuan Gaoke Cable Co., Ltd.

Angelegenheiten, die nicht in dieser technischen Spezifikation erwähnt sind, werden vom Käufer und Lieferanten ausgehandelt. Dieses Dokument bestätigt die Vereinbarung beider Parteien als technische Vertragsvereinbarung, sofern in den offiziellen schriftlichen Anlagen nichts anderes bestimmt ist.


2. ANWENDBAR STANDARDS

Das angebotene Kabel muss gemäß den folgenden internationalen Normen entworfen, hergestellt und geprüft werden:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 60840

Power cables with extruded insulation and their accessories for rated voltages  above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) – Test methods and requirements

3. KABELSTRUKTUR für 66kV Kabel

cable6



CU / XLPE / LS / CWS / HDPE 38/66 (72,5) kV 1 × 1000 mm 2

Structure

   Nominal thickness mm

  Nominal diameter mm

   1 Five(5) Milliken (segmental) copper conductor

/

38.8±0.6

   2 Semi-conductive tape

0.14

39.4

   3 Conductor screen(wrapping & extruding)

2.0

42.8

   4 XLPE insulation

12.0

66.8±1.5

   5 Insulation screen

1.0

68.8

   6 semi-conductive water blocking tape

2.0

70.8

   7 lead sheath

3.0

76.8

   8 Semi-conductive water blocking tape

2.0

78.8

   9 Copper wire screen with  

c    opper tape wrapping(gap)

       Nominal sectional area 120.0mm2

81.8

   10 non-conductive water blocking tape

0.6

82.8

   11 HDPE outer sheath

4.5

91.8

   12 semi-conductive layer(extruding)

0.5

92.8±3.0

Leas-Hülle mit Kupferdraht verpflichten Verladung Kurzschlussstrom zusammen



4. Garantierte technische Einzelheiten

No

DESCRIPTION

UNIT

VALUEREQUIRED

1

Manufacturer



Beijing Huayuan Gaoke Cable.Co.,Ltd.


2

Cable size

mm2

1000(nominal)

3

Cable type


CU/XLPE/LS/CWS/HDPE

4

Voltage Grade(U0/U(Um)

KV

38/66(72.5)

5

Reference Standard


IEC 60840

6

No. and cross sectional area of conductor


1C 1000sqmm

7

Conductor material


Copper

8

Shape


Five(5) Milliken (segmental)

9

Nominal diameter of conductor

mm

38.8

10

Conductor Screen materials


Simi-conduction tape + Extruded semi-conducting compound

11

Nominal thickness of conductor screen

mm

2.0(wrapping + extruding)

12

Insulation material

 

super clean XLPE

13

Nominal thickness of insulation

mm

12.0

14

Nominal diameter over insulation

mm

66.8

15

Insulation screen material


Extruded semi-conducting compound

16

Nominal thickness of insulation screen

mm

1.0

17

Metallic Screen material


copper wire with copper tape binder tape (gap)

18

Short circuit current rating(t=1.0sec)




Of conductor

kA

144


Of metallic screen

kA

≥25(lead sheath with copper wire)

19

Outer sheath material


HDPE

 

Colour

 

yellow

20

Nominal thickness of outer sheath

mm

4.5

21

Nominal thickness of extrude semi-conductive layer

mm

0.5

22

Nominal overall diameter of cable

mm

92.8

23

Approx. weight of cable

kg/km

21860

24

Minimum bending radius

mm

2320

25

Max.D.C. Conductor resistance at20`C

Ω/km

0.0176

26

Nominal capacitance per phase

uF/km

0.30

27

Max. current rating in air at  40° C

A

1442(1 circuit ,phase spacing  250, flat formation, a point earthed or cross connected)

28

Max. current rating in ground at 25° C

A

1273circuit ,phase spacing  250, flat formation, a point earthed or cross connected ,depth of laying 1200 mm ,thermal resistivity of soil 1.0 k.m/W)

29

Max. conductor temperature on continuous

90

30

Max. conductor temperature in short circuit

250(not exceed 5s)

5. TESTANFORDERUNGEN FÜR EHV-Stromkabel

Die Kabelprüfung muss gemäß der geltenden Norm für 66-kV-Stromkabel durchgeführt werden. Die folgenden Prüfgegenstände müssen in Übereinstimmung mit den relevanten IEC-Normen ausgeführt werden.

No.

Test item

Routine tests

1

Partial discharge test

2

Voltage test

3

electrical test on oversheath of the cable

Sample tests

1

conductor examination

2

measurement of electrical resistance of conductor and of metal screen/sheath

3

measurement of thickness of insulation and oversheath

4

measurement of thickness of metal sheath

5

measurement of diameters

6

hot set test for XLPE  insulation

7

measurement of capacitance


Unternehmen

undefined


Werkstatt

undefined

Paket

undefinedundefined


Lieferung und Zahlung

undefined

undefined

Ehre

undefined

Kunde

undefined



Anfrage absenden

Produktalarm

Abonnieren Sie Ihre interessierten Schlüsselwörter. Wir werden die neuesten und heißesten Produkte frei in Ihren Posteingang senden. Verpassen Sie keine Handelsinformationen.