Model No. : YJLW02
Brand Name : HUAYUAN YONGTONG
Type : Insulated
Conductor Type : Stranded
Application : Underground
Conductor Material : Copper
Sheath Material : Crosslinking
Insulation Material : XLPE
Material Shape : Round Wire
Range of Application : Refractory
Brand : HUAYUAN YONGTONG
mehr
8yrs

Beijing, Beijing, China

Besuchen Sie den Laden
  • Plattformzertifizierung
  • Video

Produktbeschreibung

1. ALLGEMEINES

Diese gelistete Spezifikation deckt die Struktur, Leistung, Test- und Verpackungsinformationen von HV-Stromkabeln ab, die von Beijing Huayuan Gaoke Cable Co., Ltd. hergestellt werden.

Angelegenheiten, die nicht in dieser technischen Spezifikation erwähnt sind, werden vom Käufer und Lieferanten ausgehandelt. Dieses Dokument bestätigt die Vereinbarung beider Parteien als technische Vertragsvereinbarung, sofern in den offiziellen schriftlichen Anlagen nichts anderes bestimmt ist.

2.APPLICALBE STANDARDS

Das c muss nach internationalen Standards wie folgt entworfen, hergestellt und geprüft werden:

Quality Control Standard

ISO 9001

Quality Management Systems

ISO 14001

Environmental Management Systems

Component Material Standard

IEC 60228

Conductors of insulated cables

Cable Standard

IEC 62067

Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) - Test methods and requirements

3.KABELSTRUKTUR FÜR 1C * 1600 MM2 KABEL

500kv 1x1600mm2


CU / XLPE / CAS / PVC 290/500 (550) kV 1 × 1600 mm 2

structure

Nominal thickness

mm

Nominal diameter

mm

1 Copper Conductor(5 segmental)

/

48.7± 0.6

2 Semi-conductor tape

0.14

49.7

3 Conductor screen (wrapping +extruding)

2.5

53.7

4 XLPE insulation

32.0

117.7(-1.5,+1.5)

5 Insulation screen

1.5

120.7

6 Semi-conductor water blocking tape

2.0

129.4

7 Corrugated aluminum sheath(Welding)

3.1

149.5

8 Corrosion resistant layer (Asphalt )

0.25

150.0

9 PVC Outer jacket

6.0

162.0

10 Graphite coating

 

162.0±3.0

4. GARANTIERTE TECHNISCHE DATEN

No

DESCRIPTION

UNIT

VALUEREQUIRED

1

Manufacturer


Beijing Huayuan

2

Cable size

mm2

1600

3

Cable type


CU/XLPE/CAS/PVC

4

Voltage Grade(U0/U(Um)

KV

290/500(550)

5

Reference Standard


IEC 62067 IEC60228

6

No. and cross sectional area of conductor

 

1C 1600mm2

7

Conductor material


Copper

8

Shape


5 segmental

9

Nominal diameter of conductor

mm

48.7

10

Conductor Screen materials


Simi-conduction tape + Extruded semi-conducting compound

11

Nominal thickness of conductor screen

mm

2.5(wrapping +extrusion)

12

Insulation material

 

XLPE

13

Nominal thickness of insulation

mm

32.0

14

Nominal diameter over insulation

mm

117.7

15

Insulation screen material


Extruded semi-conducting compound

16

Nominal thickness of insulation screen

mm

1.5

17

Materials metallic Sheath


Aluminum(welding)

18

Nominal thickness of metallic sheath

mm

3.1

19

Short circuit current rating(t=1.0sec)




Of conductor

kA

230

 

Of metal screen with metal sheath

kA

142

20

Outer sheath material


PVC

21

Nominal thickness of outer sheath

mm

6.0

22

Nominal diameter of cable

mm

162.0

23

Approx. weight of cable

Kg/km

31790

24

Minimum bending radius

mm

3240

25

Max.D.C. Conductor resistanceat20`C

Ω/km

0.0113

26

Nominal capacitance per phase

uF/km

0.170

27

Max. current rating in air(a point earthed or cross connected)

A

1712( temperature 40° C , 1 circuit ,phase spacing 300, flat  formation)

28

Max. current rating in underground(a point earthed or cross connected)

A

1(temperature 40° C , depth  of laying 1200 mm ,thermal resistivity of soil 1.0 k.m/W , phase spacing 300 , flat  formation)

29

Max. current rating in direct burial(a point earthed or cross connected, temperature 35℃,1 circuit)

A

1128(temperature 25° C , depth  of laying 1500 mm ,thermal resistivity of soil 1.0 k.m/W, phase spacing  300, flat  formation)

30

Max. conductor temperature on continuous

90

31

Max. conductor temperature in short circuit

250(not exceed 5s)

5.TESTANFORDERUNGEN FÜR HV-KABEL

Die Kabelprüfung muss gemäß dem geltenden Standard für 275-kV-Stromkabel durchgeführt werden. Die folgenden Prüfgegenstände müssen in Übereinstimmung mit den relevanten IEC-Normen ausgeführt werden.

No.

Test item

Routine tests

1

Partial discharge test

2

Voltage test

3

electrical test on oversheath of the cable

Sample tests

1

conductor examination

2

measurement of electrical resistance of conductor and of metal screen/sheath

3

measurement of thickness of insulation and oversheath

4

measurement of thickness of metal sheath

5

measurement of diameters

6

hot set test for XLPE  insulation

7

measurement of capacitance


6. VERPACKUNGSHINWEISE FÜR 500 KV-KABEL

Die Kabel sind auf Einweg-Stahlfässern aufzuwickeln. Die unlöschbare Markierung muss gemäß den Kundenanforderungen auf die Oberfläche des Trommelflansches gedruckt werden.

Drumpackage 1



Fabrik und Ausrüstung

power cable durm

middle voltage package1


Paket



Ehre

Certificates


Anfrage absenden

Produktalarm

Abonnieren Sie Ihre interessierten Schlüsselwörter. Wir werden die neuesten und heißesten Produkte frei in Ihren Posteingang senden. Verpassen Sie keine Handelsinformationen.